Oftentimes it is helpful to select specific events from a sample and re-run the full simulation of them while storing more simulation detail about what transpired. Thanks to the excellent work by Einar Elén in SimCore #95 we are able to re-run the simulation using an input file and optionally specifying specific events to re-simulate.

Basics

A key component of re-simulation is to keep the physics configuration of the simulation identical to what it was originally. With this in mind, the suggested procedure is to make a copy of the original file used to run the simulation and then make the following changes.

  1. Use the previous output file as the input file
  2. Tell the simulator to resimulate when adding it to the p.sequence

For change (1), I usually provide the previous output file as a command line argument to the fire config script and so I have something like this in my re-sim config.

import sys
import os
p.inputFiles = [ sys.argv[1] ]
p.outputFiles = [ 'resim_'+os.path.basename(sys.argv[1]) ]

This writes the resim events into a file with the same name as the original but with a resim_ prefix added into the current directory.

For change (2), this is where you can optionally provide which events you wish to select for re-simulation.

p.sequence = [
  # sim is the simulator object created and configured earlier
  sim.resimulate(which_events = [42])
  # potentially other processors like normal
]

The which_events aregument is a integer list giving the event numbers from that file that you wish to re-simulate. If which_events is not given, then all of the events in the input file are re-simulated.

That's it! Running the updated copy of the simulation config will re-simulate events from the original simulation in an identical manner. This plain re-simulation may not be very helpful on its own, so below we have a few other modifications that could be made to make the re-simulation more helpful.

Running additional processors after re-simulation

After running the re-simulation, the output file will contain both the original sim-hit collection from the input file and the new one from the re-simulation. This means that if you want to run any processors after the simulation that use the collections, you either need to manually specify the re-sim pass name or drop the original collection (recommended).

If you want to run producers after the re-simulation, it is usually easiest to do so with a separate configuration that uses the re-simulation output as an input-file and dropping the original collections during the re-simulation.

As an example, if you wanted to run the Ecal reconstruction chain on a resimulation with pass-name "resim"

# Resim config file 
p = ldmxcfg.Process('resim') 
# ...
p.inputFiles = ['original_simulation.root'] # Pass name "sim"
p.outputFiles = ['resimulation.root'] # Pass name "resim"
# Drop all collections that end with SimHits_sim
p.keep ["drop .SimHits_sim"] 

And later in your reconstruction config

# Resim config file 
p = ldmxcfg.Process('reconstruct') 
# ...
p.inputFiles = ['resimulation.root'] # Pass name "resim"
p.sequence = [
  ecal_digi, 
  ecal_reco
]

Alternatively, you can do it all in one configuration but you will have to manually specify the pass name for each processor that relies on simulated hits that you want to use. Unfortunately, different processors have different naming conventions for the pass name parameter so you will have to check manually how to do it for the processor that you are interested in.

# Resim config file 
p = ldmxcfg.Process('resim') 
# ...
p.inputFiles = ['original_simulation.root'] # Pass name "sim"
p.outputFiles = ['resimulation.root'] # Pass name "resim"

# Digi producer needs the raw simhits 
ecal_digi = ...  
ecal_digi.inputPassName = 'resim' # Pick the resim version

p.sequence = [
  resim, 
  ecal_digi, 
  ecal_reco # Doesn't directly rely on simhits, so doesn't need pass name to be specified!
]

The latter approach gets cumbersome if you want to use more than a couple of processors.

Producing more details about specific events

A common use-case for resimulation is when you have a subset of your events that you are particularly interested in (e.g. EcalPN reactions that pass the BDT veto). Repeating the simulation of just those events can allow you to record details that would otherwise consume too much space or insert additional instrumentation into the simulation (either directly in code or with tools/flags from ldmx-sw).

Printing particle histories

In the Biasing submodule, there is a UserAction available that will print out the full step history for one or more particles in an event. For anything longer than a couple events, this would entirely swamp the log with excessive detail. However, if you run the resimulation which only repeats the events you are interested in, this becomes a powerful tool for understanding what happened during the simulation.

# Import the utility set of actions from the Biasing submodule 
from LDMX.Biasing import util 
resim.actions.extend([
  util.StepPrinter(track_id=1), # Print the primary particle 
  util.StepPrinter(process_type='photonNuclear'), # Print any photonuclear products
])

Storing all Simulated Particles

The shower that happens in the calorimeters often creates many hundreds or even thousands of simulated particles. Thus we cannot save all of the simulated particles for all of our events - otherwise we would run out of storage space on our computers! Checkout Which SimParticles are saved? to learn more about how this choice is made. For our purposes here, if your simulation configuration has no UserActions setting the SaveFlag to false (which is highly likely), then we can insure that the simulation saves all of the simulated particles by setting StoreTrajectories to true everywhere.

First, make a local copy of the detector you are simulating so that you can reference it within the config script.

cp path/to/ldmx-sw/install/data/detectors/<detector-name>/detector.gdml .

Update this detector to have all StoreTrajectories flags set to true.

sed -i '/StoreTrajectories/ s/false/true/g' detector.gdml

Finally, update the re-simulation config to use this slightly modified detector instead of the original copy at the install location.

# above we construct the simulator object sim
sim.setDetector( '<detector-name>' )
# update the path to use the new root detector.gdml with updated flags
#   here, we use a relative path and so we must run the config from the
#   directory where the edited detector.gdml is
sim.detector = 'detector.gdml'

Now when the re-simulation is run, all of the simulated particles will be in the output file giving you as much detail about the particles and the processes that they underwent as we can give from ldmx-sw (without modifying the C++ source code).

As mentioned earlier, this stores a lot of particles (most of which are not important), so this should only be done on small numbers of events (less than 100) to avoid the files from getting too large and unweildy. In a production scenario, it would be better to write your own UserAction which finds the particles that interest you rather than storing all of the particles that are created.

No Merging of Ecal Simulated Hits

Similar to the simulated particles, the number of simulated hits in the ECal is generally too large and so we do a somewhat complicated procedure of merging them in order to reduce the size of the output data file. There is a standing issue focused on improving this merging algorithm SimCore #31 and if that issue is resolved, the parameters of the merging will likely change.

The EcalSD class is what handles each of the simulated hits created while Geant4 is processing an event. It has two parameters for modifying how these hits should be created.

  • enableHitContribs, if True, allows EcalSD to create SimCalorimeterHit "contribs" when more than one hit occurs within the same Ecal cell. If False, all hits within a cell are combined by summing their respective energy deposits and choosing the earliest time.
    • The default is True.
  • compressHitContribs is only used is enableHitContribs is True. If compressHitContribs is True, then a new contrib is only created for unique simulated particles. In other words, a contrib for a specific simulated particle is updated with more energy deposited and another deposit time if another hit is made by that simulated particle in the same ECal cell. If False, a new contrib is created for all simulated hits regardless on if any of the contribs originate from the same simulated particle.

The compressHitContribs is the parameter which causes the most confusion when interpreting ECal simulated hit information and so removing it will give you a contrib for each simulated hit created by Geant4 within the ECal. The code to put into your re-sim config is below.

# sim is a simulator object created earlier
# must be done _after_ sim.setDetector is called
for sd in sim.sensitive_detectors:
    if 'EcalSD' in sd.class_name:
        sd.compressHitContribs = False

Warning

The ECal digi-emulation and reconstruction pipeline has only been developed and tested with the default settings of the simulated hit merging. This means you should probably remove the ECal pipeline (or prepare yourself to help develop it) if you start playing with these parameters.

Other Detector Designs

The two prior examples are all about storing more information during the re-simulation process so that certain "special" events can be studied in more detail. One could also imagine studying how a select set of "special" events behave within a modified detector. Technically, this is easy - simply change the name provided to setDetector or specify a relative path like is done when saving all of the sim particles above. However, there is a big caveat.

The random number generation in Geant4 is sequential. This means psuedo-random numbers are "created" one-after-another and then given to the process requesting a random number. The simulated events will only be identical if the requests from different functions are done in the same exact order in order to preserve the assignment of psuedo-random numbers to their roles in the simulation. We can initiate this process correctly by setting up the RNG (random number generator) to be in the same state as it was at the beginning of the original simulated event (what we call the eventSeed in the event header represents this state); however, if the simulation is not configured the same as before, the order of random number requests can change leading to different simulation results even though we used the same initial state of the RNG.

With this disucssion of RNGs aside, I can get to the point: The "special-ness" of an event needs to be "decided earlier" than where the detector is being changed. By "special-ness", I mean what happens within the simulation that causes this event to be interesting (for example, a particularly nasty photon-nuclear interaction followed by a kaon decay). By "decided earlier", I mean that this "special-ness" process needs to happen in a detector volume that is processed by Geant4 before any of the detector volumes that are being changed. For example, if we want to inspect how changes to the HCal can help veto particularly nasty ECal photon-nuclear events, that is ok because we are not changing the ECal where the "special" stuff occurs. We cannot change the ECal itself and expect the re-simulation to re-play the same "special" process since the RNG may not follow the same path. Similarly, we cannot change the tagger or recoil or anything upstream of the ECal for fear of it affecting the RNG.