LDMX Software
ESA 2026 HCal detector map

connections.csv for HcalDetectorMap.esa26(): HCal of the ESA 2026 cosmic stand, HGCROC 0, 2, 3 on one ECON-D. Explicit format: electronics ID (Polarfire = ECONDDecoder fiber 0, Elink = ECON-D eRx, Channel 0-35) to HcalDigiID (Section, Layer, Strip, End). HGCROC, RocChannel, Plane and Cable are for reference.

Sources:

  • LDMX Cosmic Cabling Convention.xlsx (UVA, 31-Oct-26): HGCROC channel, CMB, plane and cable of each bar end; top-down drawings of the 3-quad and 2-quad planes; side views with the ROC per station.
  • eRx to HGCROC half measured on run 209 (pedestals per eRx match one pflib ROC half each): eRx 0-5 = ROC3 upper, ROC3 lower, ROC0 upper, ROC0 lower, ROC2 lower, ROC2 upper.

Placement (sections and layers as in the cosmic26_v2 geometry, layers from the top):

  • Planes 1-4: top station (section 1), layers 1-4. Planes 1, 2 are the short pair (the ESA25 quads, 1 m bars), planes 3, 4 the long pair.
  • Planes 5-8: above the ECal (section 0), layers 1-4.
  • Planes 9-12: below the ECal (section 2), layers 1-4. ROC1 (planes 10, 12) is not installed.
  • "Side 1" planes (ROC0, ROC1) have bars along y, "Side 2" planes (ROC2, ROC3) along x. With plane numbers increasing downwards this matches the alternation of all three stations in the GDML.

192 of 216 channels are mapped: 64 belong to uninstalled cables, 24 are the unconnected every-ninth channels.

Strip order corrected with cosmic tracks (run 227, zero suppression, 4.8 h): in the stations above and below the ECal one end of each bar had its strip order reversed within each group of 4 bars, so the two ends landed on mirrored bars. Tracks anchored in the top station (where the ends agree) vote for the end on the straight line: the reversed end is end 0 on planes 5, 9 and 11 (cables J4, J1-J3, J5-J7) and end 1 on plane 7 (J16). After the correction the two ends agree in all but 3 of about 4000 two-end hits. Planes 6 and 8 (above the ECal, bars along y, half read) show the same mirror. Resolved with runs 294-296 (11 h, ZS): referenced to the ECal L2 pads, end 1 of plane 6 and end 0 of plane 8 are the reversed ends. After the correction planes 6 and 8 count their strips the same way (before: strip correlation -0.87), and as plane 3 of the top station.

Provisional: the drawings fix left/right only relative to the front. Front is taken at -y (right at +x). If the front is at +y, the strip order and the two ends flip in every layer.